WGJ-S DUO PP

characteristics

Exchangers are designed to heat and store hot water for the needs of flats, single- and multi-family homes and other objects equipped with a low-temperature hot water boilers of any type.

The tank is covered inside with a layer of special high temperature ceramic enamel.

 

Available models:

 

Catalog number Model EAN
066-25-206/PP WGJ-S 250 DUO PP 5903538245101
066-30-206/PP WGJ-S 300 DUO PP 5903538245118
066-40-206/PP WGJ S 400 DUO PP 5903538245125

 

technical information
Technical parameters
Type Unit WGJ-S 250 DUO PP WGJ-S 300 DUO PP WGJ-S 400 DUO PP
Tank capacity dm³ 246 299 411
Heat exchanger area bottom top bottom top bottom top
1,1 0,8 1,4 1,0 1,6 1,1
The capacity of the coil dm³ 6,4 4,3 8,0 5,7 9,5 6,3

Efficiency hot water

80/10/45°C

70/10/45°C

6010/45°C

dm³/h

 

629

526

378

 

442

368

270

 

826

727

506

 

595

504

361

 

948

826

600

 

629

526

378

 
Heating power

80/10/45°C

70/10/45°C

6010/45°C

kW

 

25,6

21,4

15,4

 

18,0

15,0

11,0

 

33,6

29,6

20,6

 

24,2

20,5

14,7

 

38,6

33,6

24,4

 

25,6

21,4

15,4

Efficiency hot water

80/10/60°C

70/10/60°C

dm³/h

 

354

227

 

264

198

 

450

279

 

326

206

 

523

330

 

354

227

Heating power

80/10/60°C

70/10/60°C

kW

 

20,6

13,2

 

15,4

11,5

 

26,2

16,2

 

19,0

12,0

 

30,4

19,2

 

20,6

13,2

Heating water flow in the coil m³/h 1,8 1,4 2,2 1,7 2,6 1,9
Loss of pressure
mbar 40 25 70 35 110 90
Standing loss** W 61 73 59
ErP Efficiency Class**   B C B
Operating parameters of the tank  

Maximum operating pressure and temperature pr = 0,6 MPa tr = 80°C

The parameters of the heating medium  

Maximum operating pressure and temperature pr = 0,6 MPa tr = 100°C

Type of tank
  steel covered inside with ceramic enamel
Type of the outer housing   plastic or skay
Thermal isolation
  70 mm polystyrene foam or 60 mm polyurethane foam 100 mm polystyrene foam
Weight kg 105 130 210

*80°C, 70°C, 60°C - heating water entering the coil

 10°C - temperature of the water flow

 60°C; 45°C - temperature hot water

** in accordance with applicable since 26 September 2015. EU Commission Regulation No. 812/2013

 

Dimensions
Type Unit WGJ-S 250 DUO PP WGJ-S  300 DUO PP WGJ-S 400 DUO PP
Capacity dm³ 246 299 411
Height isolation PS H mm 1600 1900 1850
isolation PUR 1580 1880 -
The maximum height at an inclination isolation PS H* mm 1730 2010 2020
isolation  PUR 1700 1985 -
Diameter isolation  PS D mm 650 650 810
isolation PUR 630 630 -
Cold water ZW ¾" ¾" 1 ¼"
B mm 250 250 330
Hot water CW ¾" ¾" 1 ¼"
N mm 1270 1570 1470
Heating water flow - top coil WEG 1" 1" 1"
L mm 1090 1320 1380
Heating water return - top coil WYG 1" 1" 1"
J mm 850 1000 1060
Heating water flow - bottom coil (solar) WED 1" 1" 1"
G mm 700 790 880
Heating water return - bottom coil (solar) WYD 1" 1" 1"
C mm 330 330 420
Connector horseshoes KP 1" 1" 1"
M mm 1180 1480 1290
E mm 420 420 510
Circulation RC ¾" ¾" ¾"
I mm 790 900 970
Muff temperature sensor CT ½" ½" ½"
K mm 1000 1140 1200
F mm 510 510 600
Muff heater MG 1½" 1½" 1½"
P mm 895 1030 1110
Muff thermometer RT ½" ½" ½"
R mm 895 1510 1445
The capillary tube closed - long RK ½" ½" ½"
T mm 895 1030 1110
S mm 325 325 425
Magnesium anode AN 2" 2" 2"
Ø x L 40 x 330 40 x 390 40 x 430
Cleaning hole W 2" 2" Ø 130
O mm 310 310 400
Drain ZS ¾" ¾" ¾"
A mm 80 80 95

 

unfold fold