Nordic Combi Elektronik

characteristics

NORDIC COMBI ELEKTRONIK  is a universal heater with a capacity 80-140l. It has a spiral coil and an electric heater 2 x 1.2 kW; 230V; with a programmable electronic thermostat.

 

Programmable electronic controller works in a weekly cycle and has functions:

  •  water protection against freezing,
  •  the possibility of heating water in the low tariff hours (electricity prices),
  •  possibility to heat the water for a certain period of time.

 

Heaters are adapted for suspension in an upright position.

 

Available models:

 

Catalog number Model EAN
014-08-931/3 NORDIC COMBI ELEKTRONIK 80 5903538235188
014-10-931/3 NORDIC COMBI ELEKTRONIK 100 5903538235225
014-12-931/3 NORDIC COMBI ELEKTRONIK 120 5903538235263
014-14-931/3 NORDIC COMBI ELEKTRONIK 140 5903538235300

 

technical information

Technical parameters
Type Unit NORDIC COMBI ELEKTRONIK
80 100 120 140
Storage capacity dm³ 73 91 110 128
The surface of the coil 0,9 1,1 1,3 1,6
The capacity of the coil dm³ 4,0 5,0 6,0 7,4

Constant efficiency of the hot water*

80/10/45°C

70/10/45°C

60/10/45°C

dm³/h

 

337

253

190

 

412

308

231

 

490

368

276

 

600

450

337

Constant heating power*

80/10/45°C

70/10/45°C

60/10/45°C

kW

 

15,3

11,5

8,6

 

18,7

14,0

10,5

 

22,3

16,5

12,5

 

27,2

20,4

15,3

The initial performance of the hot water (initial temperature 60°C)

80/10/45°C

70/10/45°C

dm³/10min

 

125

115

 

155

145

 

180

165

 

220

205

Daily consumption of electricity** kWh 7,05 7,73 7,31 7,51
Load profile**   M M M M
Sound power level** dB 15 15 15 15
The amount of mixed water with temp. 40°C** dm³ 110 138 154 169
Energy efficiency** % 34,7 32,5 33,8 33,1
Demand for heating water m³/h 3 3 3 3
The resistance of the water flow in the coil mbar 50 70 95 120
Operating parameters of the tank Maximum operating pressure and temperature pr = 0.6 MPa tm = 80°C
The parameters of the heating medium Maximum operating pressure and temperature pr = 0.6 MPa tm = 100°C
Weight of the heater kg 51 60 69 77
ErP Efficiency Class**   D D D D
WE – heating water flow   external thread  ¾"
WY – heating water return   external thread  ¾"
CR – circulation   external thread  ½"
ZW – cold water   external thread ½"
CW – hot water   external thread ½"
CT – temperature sensor   Ø16

*80°C, 70°C, 60°C - heating water temperature at the entrance to the coil

                         10°C -temperature of the cold water

                         45°C - temperature of the hot water

* in accordance with applicable since 26 September 2015. EU Commission Regulation No. 812/2013

Dimensions
MODEL A B
NORDIC COMBI 80 900 420
NORDIC COMBI 100 1060 580
NORDIC COMBI 120 1220 740
NORDIC COMBI 140 1380 900

 

 

unfold fold