Beta plus
Electric water heaters BETA-plus are designed to heat and store hot water for sanitary, social and economic needs. These are pressure device designed to work in the upright position with connections at the inlet and outlet water to the bottom, with a maximum pressure of water in the tank 0.6 MPa (6 bars).
Models are available with a capacity of 80, 100, 120, 140 liters of connecting routes from the right or left side.
Catalog number | Model | EAN |
014-08-211/L | Beta plus 80 | 5903538202548 |
014-08-211/P | Beta plus 80 | 5903538202555 |
014-10-211/L | Beta plus 100 | 5903538202562 |
014-10-211/P | Beta plus 100 | 5903538202579 |
014-12-211/L | Beta plus 120 | 5903538202586 |
014-12-211/P | Beta plus 120 | 5903538202593 |
014-14-211/L | Beta plus 140 | 5903538202609 |
014-14-211/P | Beta plus 140 | 5903538202616 |
Type heater | Unit | BETA plus 80 | BETA plus 100 | BETA plus 120 | BETA plus 140 | |
Capacity | dm³ | 67 | 85 | 110 | 130 | |
Heat exchange surface | m² | 0,76 | 0,76 | 1,05 | 1,05 | |
The capacity of the coil | dm³ | 3,35 | 3,35 | 6,35 | 6,35 | |
Efficiency of the hot water* | 80/10/45°C 70/10/45°C 60/10/45°C | dm³/h | 452 383 275 | 452 383 275 | 612 516 371 | 612 516 371 |
Heating power of the coil* | 80/10/45°C 70/10/45°C 60/10/45°C | kW | 18,4 15,6 11,2 | 18,4 15,6 11,2 | 25,0 21,0 15,1 | 25,0 21,0 15,1 |
Heating water flow in the coil | m³/h | 1,5 | 1,5 | 1,5 | 1,5 | |
Warm-up time for Δt=50°C for heater 2000 W | h | 2,3 | 2,9 | 3,5 | 4,1 | |
Daily consumption of electricity** | kWh | 7,60 | 7,64 | 7,67 | 7,71 | |
Load profile** | M | M | M | M | ||
Sound power level** | dB | 15 | 15 | 15 | 15 | |
The amount of mixed water with temperature 40°C** | dm³ | 110 | 142 | 185 | 220 | |
Energy efficiency** | % | 32,9 | 32,8 | 32,7 | 32,5 | |
ErP Efficiency Class** | D | D | D | D | ||
Operating parameters of the tank | Pmax = 0,6 MPa; Tmax = 80°C | |||||
The parameters of the heating medium | Pmax = 0,6 MPa; Tmax = 100°C |
*80°C, 70°C, 60°C - heating water temperature at the entrance to the coil,
10°C - temperature of the water flow, 45°C - temperature of the hot water
* in accordance with applicable since 26 September 2015. EU Commission Regulation No. 812/2013
Type | Unit | BETA - plus 80 | BETA - plus 100 | BETA - plus 120 | BETA - plus 140 | |
H | mm | 970 | 1160 | 1190 | 1350 | |
h | mm | 885 | 1075 | 1120 | 1280 | |
Connector water | CW/ZW | external thread - ½" | external thread - ½" | external thread - ½" | external thread- ½" | |
Coil connector | WE/WY | internal thread- ¾" | internal thread - ¾" | internal thread - ¾" | internal thread - ¾" | |
Temperature sensor connection | CT | internal thread- ½" | internal thread - ½" | internal thread - ½" | internal thread - ½" | |
Connector circulation | RC | internal thread - ½" | internal thread - ½" | internal thread- ¾" | internal thread - ¾" | |
Magnesium anode on the cork 5/4" | AN | mm | Ø 25 x 225 | Ø 25 x 300 | Ø 30 x 270 | Ø 30 x 270 |
Weight of heater without water | kg | 42 | 48 | 62 | 68 |