WGJ-g DWP
characteristics
Double-shell heaters - water heat exchangers WGJ-g DWP are designed to heat and store hot water for the needs of apartments, houses, workshops, etc.
The tank is covered inside with a layer of special high temperature ceramic enamel.
Available models:
| Catalog number | Model | EAN |
| 223-12-600 | WGJ-g DWP 120 | 5903538238301 |
| 223-14-600 | WGJ-g DWP 140 | 5903538238318 |
technical information
| Parameter | Unit | WGJ-g DWP 120 | WGJ-g DWP 140 | |
| Actual capacity of the exchanger | dm³ | 112 | 125 | |
| Sheathed exchanger | Heat exchanger area | m² | 0,82 | 0,95 |
| Efficiency hot water. 70/10/45°C* | dm³/h | 500 | 580 | |
| Constant heating power 70/10/45°C* | kW | 20 | 23 | |
| Coil | The exchange surface of the coil | m² | 0,50 | 0,54 |
| Efficiency hot water 70/10/45°C* | dm³/h | 255 | 280 | |
| Constant heating power 70/15/45°C* | kW | 10,8 | 11,5 | |
| Standing loss** | W | 49 | 53 | |
| ErP Efficiency Class** | B | B | ||
| Operating parameters of the water tank | maximum pressure and operating temperature pr = 0,6 MPa tr = 80°C | |||
| The parameters of the heating medium in the exchanger jacketed | maximum pressure and operating temperature pr = 0,2 MPa tr = 100°C | |||
| The parameters of the heating medium in the coil | maximum pressure and operating temperature pt = 0,6 MPa tr = 100°C | |||
| Thermal isolation | about 50 mm polystyrene foam | |||
*70°C - heating water temperature at the entrance to the coil or the exchanger jacketed
10°C - temperature of the water flow
45°C - temperature hot water
** in accordance with applicable since 26 September 2015. EU Commission Regulation No. 812/2013
| Dimensions | Unit | WGJ-g DWP 120 | WGJ-g DWP 140 |
| D | mm | 530 | 530 |
| H | mm | 1120 | 1220 |
| E | mm | 920 | 1020 |
| F | mm | 805 | 905 |
| A | mm | 190 | 190 |
| B | mm | 305 | 305 |
| W | mm | 260 | 260 |
| P | mm | 200 | 200 |
| Muff ZW - supply of cold water | ¾" | ¾" | |
| Muff CW - the outflow of hot water | ¾" | ¾" | |
| Muff WE - inlet hot water boiler | 1" | 1" | |
| Muff WY - boiler water outlet | 1" | 1" | |
| Coil connector KW | 1" | 1" | |
| Connector pipe connections for "horseshoes" MP | 1" | 1" | |
| Muff circulation RC | ½" | ½" | |
| Muff heater | 1½" | 1½" | |
| Connector pipe heater | 1½" | 1½" | |
| Tube thermometer RK | mm | Ø 12 | Ø 12 |
| Cork of the anode AN | 1¼" | 1¼" | |
| Magnesium anode | Ø 25 x 350 | Ø 30 x 270 | |
| Thermal isolation | 50 mm polystyrene foam | ||
| The weight of the exchanger without water | kg | about 57 | about 63 |
| Exchanger typ | Unit | WGJ-g DWP 120 | WGJ-g DWP 140 | |
| F | mm | ~450 | ~550 | |
|
L min. | EJK-1500 EJK-2000 | mm | 500 | 500 |
| EJK-3000 | mm | 430 | 430 | |
| EJK-4500 | mm | 540 | 540 | |
| EJK-6000 | mm | 650 | 650 | |
| M min. | mm | 400 | 300 | |