WGJ-S, casing skay

characteristics

Exchangers WGJ-S are designed to heat and store hot water for the needs of flats, houses, small buildings and other objects equipped with low-temperature boilers of any type.

They are produced in versions with one coil: WGJ-S, WGJ-S FIT .

The tank is covered inside with a layer of special high temperature ceramic enamel.

 

Available models:

 

Catalog number Model EAN
066-10-106 WGJ-S 100 5903538204504
066-12-106 WGJ-S 120 5903538204511
066-15-106 WGJ-S 150 5903538204528
066-22-106 WGJ-S 220 FIT 5903538204757
066-25-106 WGJ-S 250 FIT 5903538204566
066-30-106 WGJ-S 300 FIT 5903538204597
066-40-106 WGJ-S 400 5903538204627
066-50-106 WGJ-S 500 5903538204658
066-75-106 WGJ-S 750 5903538204689
066-01-106/28 WGJ-S 1000 5903538204719
066-01-106/37 WGJ-S 1000 5903538204726
066-01-106/48 WGJ-S 1000 5903538204733

Tank with a capacity of 1000 liters is available with coil of the exchange surface 2.8, 3.7 or 4.8 m².

technical information
Technical parameters WGJ-S 100-150, WGJ-S FIT 220-300
Type Unit WGJ-S 100 WGJ-S 120 WGJ-S 150 WGJ-S 220 FIT WGJ-S 250 FIT WGJ-S 300 FIT
Usable volume of the tank dm³ 104 116 147 212 252 307
Heat exchanger surface 0,9 0,9 0,9 1,1 1,1 1,4
The capacity of the coil dm³ 5,0 5,0 5,0 6,4 6,4 8,0

Efficiency hot water

80/10/45°C

70/10/45°C

60/10/45°C

l/h

 

522

441

315

 

522

441

315

 

522

441

315

 

629

526

378

 

629

526

378

 

826

727

506

Heating power

80/10/45°C

70/10/45°C

60/10/45°C

kW

 

22,0

18,0

13,5

 

22,0

18,0

13,5

 

22,0

18,0

13,5

 

25,6

21,4

15,4

 

25,6

21,3

15,4

 

33,6

29,6

20,6

Efficiency hot water

80/10/60°C

70/10/60°C

l/h

 

294

185

 

294

185

 

294

185

 

354

227

 

354

227

 

450

279

Heating power

80/10/60°C

70/10/60°C

kW

 

17,1

10,8

 

17,1

10,8

 

17,1

10,8

 

20,6

13,2

 

20,6

13,2

 

26,2

16,2

Heating water flow in the coil m³/h 1,5 1,5 1,5 1,8 1,8 2,2
Loss of pressure mbar 30 30 30 40 40 70
Operating parameters of the tank

Maximum operating pressure and temperature pr = 0,6 MPa tr = 80°C

The parameters of the heating medium

Maximum operating pressure and temperature pr = 0,6 MPa tr = 100°C

Type of tank steel coated inside with ceramic enamel
Type the outer housing  skay type of material
Thermal isolation 60 mm of polyurethane foam
Standing loss(PUR)** W - - - 54 62 75
ErP Efficiency Class   - - - B B C
Thermal isolation 70 mm polystyrene foam
Standing loss(PS)** W 32 36 44 53 61 73
ErP Efficiency Class   A A B B B C
Weight of the heater kg 46 51 55 65 80 100

** in accordance with applicable since 26 September 2015. EU Commission Regulation No. 812/2013

 

 

 

Technical parameters WGJ-S 400-500
Type Unit WGJ-S 400 WGJ-S 500
Storage capacity of the tank dm³ 420 482
Heat exchange surface 1,6 1,9
The capacity of the coil dm³ 9,5 10,7

Efficiency hot water

80/10/45°C

70/10/45°C

60/10/45°C

dm³/h

 

948

826

600

 

1143

980

700

Heating power

80/10/45°C

70/10/45°C

60/10/45°C

kW

 

38,6

33,6

24,4

 

46,5

39,9

28,5

Efficiency hot water

80/10/60°C

70/10/60°C

dm³/h

 

523

330

 

621

392

Heating power

80/10/60°C

70/10/60°C

kW

 

30,4

19,2

 

36,1

22,8

Standing loss** W 59 67
ErP Efficiency Class**   B B
Heating water flow in the coil m³/h 2,6 3,0
Loss of pressure mbar 110 130
Operating parameters of the tank

Maximum operating pressure and temperature pr = 0,6 MPa tr = 80°C

The parameters of the heating medium

Maximum operating pressure and temperature pr = 0,6 MPa tr = 100°C

Type of tank steel coated inside with ceramic enamel
Type the outer housing skay
Thermal isolation 100 mm polystyrene foam
Weight heater kg 140 175

** in accordance with applicable since 26 September 2015. EU Commission Regulation No. 812/2013

 

 

 

 

Dimensions WGJ-S 100-150
Type Unit WGJ- S 100 WGJ-S 120 WGJ-S 150
Capacity dm³ 104 116 147
Height PS H mm 1110 1260 1460
PUR 1090 1240 1440
Max. height at an inclination PS H* mm 1245 1380 1565
PUR 1210 1345 1535
Diameter PS D mm 560 560 560
PUR 520 520 520
Cold water A mm 200 200 200
ZW ¾" ¾" ¾"
Hot water G mm 850 950 1200
CW ¾" ¾" ¾"
Heating water flow F mm 760 760 760
WE 1" 1" 1"
Heating water return B mm 300 300 300
WY 1" 1" 1"
Circulation E mm 580 580 580
RC ¾" ¾" ¾"
Muff temperature sensor - closed C mm 460 460 460
CT 3/8" 3/8" 3/8"
Muff heater J mm 260 260 260
MG 1½" 1½" 1½"
Muff thermometer I mm 790 890 1120
RT ½" ½" ½"
Magnesium anode (1) ØxL 25 x 300 25 x 300 30 x 270
AN 2" 2" 2"

 

 

 

Dimensions WGJ-S 220-500
Type Unit WGJ-S 220 FIT WGJ-S 250 FIT WGJ-S 300 FIT WGJ-S 400 WGJ-S 500
Storage capacity   212 252 307 420 482
Height insulation PS H[mm] 1400 1600 1900 1880 2180
insulation PUR 1380 1580 1880 - -
Max. height at an inclination insulation PS H*[m] 1545 1730 2010 2130 2430
insulation PUR 1520 1700 1985 - -
Diameter insulation PS D[mm] 650 650 650 840 840
insulation PUR 630 630 630 - -
Cold water A[mm] 360 250 250 360 360
ZW ¾" ¾" ¾" 1¼" 1¼"
Hot water I[mm] 1080 1270 1570 1500 1735
CW ¾" ¾" ¾" 1¼" 1¼"
Heating water flow E[mm] 650 730 820 1000 1085
WE 1" 1" 1" 1" 1"
Heating water return B[mm] 280 360 360 450 450
WY 1" 1" 1" 1" 1"
Circulation F[mm] 690 895 1030 1000 1000
RC ¾" ¾" ¾" ¾" ¾"
Muff temperature sensor - closed C[mm] 470 510 510 630 635
G[mm] 890 1000 1140 - -
CT ½" ½" ½" ½" ½"
Muff heater K[mm] 800 895 1030 1140 1245
MG 1½" 1½" 1½" 1½" 1½"
Muff thermometer L[mm] 1020 1210 1510 1480 1705
RT 1½" 1½" 1½" 1½" 1½"
The capillary tube closed N[mm] 325 325 325 455 455
K[mm] 810 905 1040 1140 1245
RK ½" ½" ½" ½" ½"
Magnesium anode Ø x L 40 x 240 40 x 240 40 x 330 40 x 390 40 x 430
AN 2" 2" 2" 2" 2"
Cleaning hole W 2" 2" 2" 100/145/175 100/145/175
M[mm] 310 310 310 430 430
Drain S[mm] 100 100 100 130 130
ZS ¾" ¾" ¾" ¾" ¾"

 

 

 

Technical parameters WGJ-S 750
Type Unit WGJ-S 750/2,5
Capacity dm³ 750
Heat exchange surface 2,5
The capacity of the coil dm³ 14,5

Efficiency hot water

80/10/45°C

70/10/45°C

60/10/45°C

dm³/h

 

1490

1285

860

Heating power

80/10/45°C

70/10/45°C

60/10/45°C

kW

 

60,7

50,4

35

Efficiency hot water

80/10/60°C

70/10/60°C

dm³/h

882

646

Heating power

80/10/60°C

70/10/60°C

kW

51,3

37,6

Heating water flow in the coil m³/h 3,5
Operating parameters of the tank

Maximum operating pressure and temperature pr = 0,6 MPa tr = 80°C

The parameters of the heating medium

Maximum operating pressure and temperature pr = 0,6 MPa tr = 100°C

The diameter of heater tank without thermal insulation mm Ø 790
The height of the heater without thermal insulation mm about 1910
Max. the height of the heater at an inclination mm about 2220
Thermal isolation 100 mm soft polyurethane foam
Magnesium anode (2 pieces) mm Ø 33 x 680
Weight heater in a housing of skay kg 265

 

 

 

Technical parameters  WGJ-S 1000
Type Unit WGJ-S 1000/2,8 WGJ-S 1000/3,7 WGJ-S 1000/4,8
Capacity dm³ 1000 1000 1000
Heat exchange surface 2,8 3,7 4,8
The capacity of the coil dm³ 16,0 21,0 27,0

Efficiency hot water

80/10/45°C

70/10/45°C

60/10/45°C

dm³/h

 

 

1800

1500

1050

 

 

2380

2000

1380

 

 

3000

2500

1730

Heating power

80/10/45°C

70/10/45°C

60/10/45°C

 

kW

70

57

40

91

76

53

115

96

67

Efficiency hot water

80/10/60°C

70/10/60°C

dm³/h

 

1260

1050

 

1660

1400

 

2100

1750

Heating power

80/10/60°C

70/10/60°C

kW

 

59

48

 

77

64

 

97

81

Initial performance (temp. Exchanger  60°C)

80/10/45°C

70/10/45°C

l/10min

 

1400

1250

 

1400

1250

 

1400

1250

Heating water flow in the coil m³/h 5,0 5,0 5,0
Loss of pressure mbar 200 250 300
Operating parameters of the tank maximum pressure and operating temperature pr = 0,6 MPa tr = 80°C
The parameters of the heating medium maximum pressure and operating temperature pr = 0,6 MPa tr = 100°C
Type of tank steel coated inside with ceramic enamel
Type the outer housing  skay
Thermal isolation 100 mm of polyurethane foam + 10 mm soft polyurethane foam
Weight heater in a housing of skay kg 400 420 480

 

 

 

 