WGJ-PC

characteristics

Exchangers type WGJ-PC 300-450 as a pressure accumulation heaters, are designed to heat and store hot water for the needs of flats, single- and multi-family homes, public, industrial and other in cooperation with low-temperature water boilers , and above all with a heat pump.

The tank is covered inside with a layer of special high temperature ceramic enamel.

 

Available models:

 

Catalog number Model EAN
052-30-206 WGJ-PC 300 5903538240984
052-45-206 WGJ-PC 450 5903538240523

 

technical information
Technical parameters WGJ-PC 300
Parameter Unit WGJ-PC 300
Tank capacity dm³ 300
Heat exchange surface 4,7
The capacity of the coil dm³ 24,5
Heating time 10-65°C 25 kW min 65
12,5 kW min 140
Heating time 10-55°C 25 kW min 50
12,5 kW min 100
Operating parameters of the tank

Maximum operating pressure and temperature pr= 0,6 Mpa tr= 80°C

The parameters of the heating medium

Maximum operating pressure and temperature pr= 0,6 Mpa tr= 100°C

Type of tank steel covered inside with ceramic enamel
Type of outer housing skay type of material
Thermal isolation 70 mm polystyrene foam
ErP Efficiency Class* C
Weight heater in a housing of skay kg about 210
Dimensions
Height mm 1880
Max. height when tilting mm 2000
Diameter mm 650
Hot water CW 1"
Cold water/drain ZW/ZS 1"
Power supply hot water heating WE 1 ¼"
Back cold water heating WY 1 ¼"
Connector thermometer RT ½"
Connector circulation RC ¾"
The capillary tube closed RK 3/8"
Connector electric heater MG 1 ½"
Cleaning hole W 133/166/195
Drain ZS ¾"
Magnesium anode AN 2" top cork 2" Ø 40 x 430
bottom cork 2" Ø 40 x 200

* in accordance with applicable since 26 September 2015. EU Commission Regulation No. 812/2013

 

 

Technical parameters WGJ-PC 450
Parameter Unit WGJ-PC 450
Tank capacity dm³ 400
Heat exchange surface 5,5
The capacity of the coil dm³ 30,5
Heating time 10-65°C 25 kW min 80
12,5 kW min 160
Heating time 10- 55°C 25 kW min 60
12,5 kW min 120
Heating time

Maximum operating pressure and temperature pr = 0,6 Mpa tr=80°C

The parameters of the heating medium

Maximum operating pressure and temperature pr = 0,6 Mpa tr=100°C

Type of tank steel covered inside with ceramic enamel
Type of outer housing skay type of material
Thermal isolation 100 mm polystyrene foam
ErP Efficiency Class* B
Weight heater in a housing of skay kg  
Height mm 1840
Max. height when tilting mm 2010
Diameter mm 810

* in accordance with applicable since 26 September 2015. EU Commission Regulation No. 812/2013

 

unfold fold