WGJ-g DUOSOL
Double-shell heat exchangers water heaters WGJ-g DUOSOL are designed to heat and store hot water for the needs of apartments, houses, workshops, etc.
The tank is covered inside with a layer of special high temperature ceramic enamel.
Available models:
Catalog number | Model | EAN |
223-20-600 | WGJ-g DUOSOL 200 | 5903538238141 |
223-25-600 | WGJ-g DUOSOL 250 | 5903538238158 |
Parameters | Unit | WGJ-g DUOSOL 200 | WGJ-g DUOSOL 250 |
D | mm | 600 | 640 |
H | mm | 1440 | 1430 |
E | mm | 1205 | 1180 |
F | mm | 1115 | 1090 |
A | mm | 235 | 245 |
B | mm | 325 | 335 |
R | mm | 325 | 365 |
Muff ZW - supply of cold water | ¾" | ¾" | |
Muff CW - drain hot water | ¾" | ¾" | |
Muff WE - hot water inlet of the boiler | 1" | 1" | |
Muff WY - boiler water outlet | 1" | 1" | |
Coil connector KW | 1" | 1" | |
Muff circulation MC | ½" | ½" | |
Muff heater MG | 1 ½" | 1 ½" | |
Connector heater KG | 1 ½" | 1 ½" | |
Tube thermometerRK | mm | Ø12 | Ø12 |
Cork anode AN | 2" | 2" | |
Magnesium anode | Ø 40 x 240 | Ø 40 x 240 | |
Thermal isolation | about 50 mm polystyrene foam | ||
The weight of heater without water | kg | 90 | 98 |
Parameters | Unit | WGJ-g DUOSOL 200 | WGJ-g DUOSOL 250 | |
Actual heater capacity | dm³ | 193 | 246 | |
Sheathed exchanger | Heat exchanger area | m² | 1,33 | 1,42 |
Capacity exchanger | dm³ | 19,3 | 20,5 | |
Efficiency hot water* 80/10/45°C 70/10/45°C 60/10/45°C | dm³/h |
960 815 555 |
1020 870 590 | |
Constant heating power* 80/10/45°C 70/10/45°C 60/10/45°C
| kW |
40 31 22 |
43 33 23 | |
Heating water flow | m³/h | 2,3 | 2,6 | |
Loss of pressure | bar | 26 | 26 | |
Coil | The exchange surface coil | m² | 0,82 | 0,96 |
The capacity of the coil | dm³ | 4,7 | 5,5 | |
Efficiency hot water* 80/10/45°C 70/10/45°C 60/10/45°C | dm³/h |
610 488 360 |
700 565 415 | |
Constant heating power* 80/10/45°C 70/10/45°C 60/10/45°C | kW |
25,5 20,3 15,0 |
29,1 23,5 17,3 | |
The exchange surface coil | m³/h | 1,6 | 1,9 | |
The capacity of the coil | mbar | 35 | 35 | |
Standing loss** | W | 70 | 77 | |
ErP Efficiency Class** | C | C | ||
Operating parameters water tank | max. pressure and operating temperature pr = 0,6 Mpa tr = 80°C | |||
The parameters of the heating medium in the exchanger jacketed | max. pressure and operating temperature pr = 0,3 Mpa tr = 100°C | |||
The parameters of the heating medium in the coil | max. pressure and operating temperature pr = 0,6 Mpa tr = 100°C | |||
Thermal isolation | about 50 mm polystyrene foam |
*60°C, 70°C, 80°C - heating water temperature at the entrance to the coil or exchanger jacketed
10°C - the temperature of water forward flow
45°C - the temperature of hot water
** in accordance with applicable since 26 September 2015. EU Commission Regulation No. 812/2013