WGJ-S/Z

characteristics
Tanks WGJ-S / Z FIT and WGJ-S / Z are designed to heat and store hot water for the needs of flats, houses, small buildings and other objects equipped with a low-temperature hot water boilers of any type.
The tank is covered inside with a layer of special high temperature ceramic enamel.

 

Available capacity:

 

Catalog number Model EAN
066-22-006 WGJ-S/Z 220 FIT 5903538204788
066-25-006 WGJ-S/Z 250 FIT 5903538204931
066-30-006 WGJ-S/Z 300 FIT 5903538204580
066-40-006 WGJ-S/Z 400 5903538204610
066-50-006 WGJ-S/Z 500 5903538204641
066-75-006 WGJ-S/Z 750 5903538204672
066-01-006 WGJ-S/Z 1000 5903538204702
Models with a capacity of 220, 250, 300 l has an outer casing made of plastic or plastic-type skay.

Models with a capacity of 400, 500, 750, 1000 l has an outer casing made out of a type of skay.

technical information
Tanks WGJ-S/Z 220-300 FIT
Type Unit WGJ-S/Z 220 FIT WGJ-S/Z 250 FIT WGJ-S/Z 300 FIT
Usable capacity dm³ 215 255 315
Operating parameters of the tank

Maximum operating pressure and temperature pr = 0.6 MPa tr = 80 ° C

Thermal isolation
70 mm polystyrene (PS)
The type of outer casing plastic or skay
ErP Efficiency Class*   B B C
Weight heater kg 60 70 92

* in accordance with applicable since 26 September 2015. EU Commission Regulation No. 812/2013

 

 

Tanks WGJ-S/Z 400-500
Type Unit WGJ-S/Z 400 WGJ-S/Z 500
Usable capacity dm³ 430 505
Operating parameters of the tank Maximum operating pressure and temperature pr = 0.6 MPa tr = 80 ° C
Type of the outer housing skay
Thermal isolation
90 mm polystyrene foam + 10 mm soft polyurethane foam
ErP Efficiency Class*   B B
Weight heater in a housing of skay kg 100 125

* in accordance with applicable since 26 September 2015. EU Commission Regulation No. 812/2013

 

 

Tanks WGJ-S/Z 750- 1000
Type Unit WGJ-S/Z 750 WGJ-S/Z 1000
Capacity dm³ 750 1000
Operating parameters of the tank Maximum operating pressure and temperature pr = 0.6 MPa tr = 80 ° C
Type of tank
steel coated inside with ceramic enamel
Type of the outer housing skay
Thermal isolation   100 mm soft polyurethane foam 100 mm of polyurethane foam
Weight heater in a housing of skay kg 220 330

 

Dimmensions of the tanks
Type Unit WGJ-S/Z 150 WGJ-S/Z 220 FIT WGJ-S/Z 250 FIT WGJ-S/Z 300 FIT WGJ-S/Z 400 WGJ-S/Z 500
Capacity dm³ 150 220 250 300 400 500
Height
PS H mm 1430 1400 1600 1900 1850 2150
PUR - 1380 1580 1880 - -
Max. altitude at an inclination PS H* mm 1565 1545 1730 2010 2100 2400
PUR - 1520 1700 1985 - -
Diameter
PS D mm 560 650 650 650 810 810
PUR - 630 630 630 - -
Cold water ZW ¾" ¾" ¾" ¾" 5/4" 5/4"
A mm 170 360 250 250 360 360
Hot water CW ¾" ¾" ¾" ¾" 5/4" 5/4"
I mm 1170 1080 1270 1570 1500 1735
Circulation
RC ¾" ¾" ¾" ¾" ¾" ¾"
F mm 550 690 895 1030 1000 1000
Muff sensor temperature CT ½" ½" ½" ½" ½" ½"
C mm 430 470 510 510 630 635
G mm - 890 1000 1140 - -
Muff heater MG 1½" 1½" 1½" 1½" 1½" 1½"
K mm 230 800 895 1030 1140 1245
Muff thermometer RT ½" ½" ½" ½" ½" ½"
L mm 960 1020 1210 1510 1480 1705
The capillary tube closed RK - ½" ½" ½" ½" ½"
K mm - 800 895 1030 1140 1245
M mm - 325 325 325 455 455
Magnesium anode ØxL mm 30x270 30x270 30x270 40x240 40x330 40x390
Muff anode AN 2" 2" 2" 2" 2" 2"
Draining ZS - ¾" ¾" ¾" ¾" ¾"
S mm - 100 100 100 130 130
Cleaning hole W - 2" 2" 2" 100/145/175 100/145/175
N mm - 310 310 310 430 430

 

unfold fold