WGJ-B INOX

characteristics
The heater that was reversed the traditional method of heating water. Domestic water flows through the fluted coil made of stainless steel. The tank also has a traditional steel coil for connecting additional external heat source which can be fireplace with a water jacket, a gas boiler or solar thermal system.
 
Available models:
 
Catalog number Model EAN
069-35-506 WGJ-B inox 350 5903538227367
069-50-506 WGJ-B inox 500 5903538227374
069-75-506 WGJ-B inox 750 5903538227114
069-10-506 WGJ-B inox 1000 5903538227176

 

technical information
Technical parameters of the tank WGJ-B inox
Type Unit WGJ-B inox 350 WGJ-B inox 500 WGJ-B inox 750 WGJ-B inox 1000
Cylinder volume - heating water dm³ 350 500 696 910

The coil of

stainless steel

Capacity of the coil of stainless steel - Hot water dm³ 18 24 43
The surface coil hot water 4,76 5,82 7,2
Heat output coil hot water kW 8 13 19 10 16 23 16 24 36
Heating water flow l/h 137 220 325 170 270 390 280 470 720
Efficiency hot water 70/10/45°C* l/h 255 390 580 315 480 710 390 590 880
Heating water flow l/h 220 370 540 285 450 650 330 650 1710
Efficiency hot water 70/10/60°C* l/h 180 270 410 220 330 500 275 410 620
Solar coil The capacity of solar coil dm³ 8 10 11 9,2
Surface of solar coil 1,4 1,75 2,36 2,4
The maximum area absorber connected to solar collector 8 10 12 12
Standing loss** W 70 67 - -
ErP Efficiency Class**   B B - -
Operating parameters of the tank

maximum working pressure pr = 0,3 MPa

maximum operating temperature  tr = 100°C

Operating parameters DHW

maximum working pressure pr = 0,6 MPa

maximum operating temperature  tr = 95°C
Operating parameters of solar installation

maximum working pressure pr =1,0 MPa

maximum operating temperature  tr = 140°C
Thermal isolation polystyrene foam 80 mm polystyrene foam 100 mm polyurethane foam 100 mm
Permanent daily energy losses kWh/24h - - 3,5 3,8
Type of the outer housing  skay
Max. height when tilting mm 2010 2300 2260 2310
Weight kg ~180 ~210 ~240 ~270

** in accordance with applicable since 26 September 2015. EU Commission Regulation No. 812/2013

 

The dimmension of connection
Connections WGJ-B inox 350 WGJ-B inox 500 WGJ-B inox 750 WGJ-B inox 1000
Heating water flow WE, WEG, WED 1" 1¼" 1" -
Heating water connection PW 1 - 8 - - - 1¼"
PW 9 - 11 - - - 1½"
Hot water CW ¾" 1" 1" 1"
Muff temperature sensor - closed CT ½" ½" ½" -
Coil solar - input WES 1" 1" 1" 1"
Cold water ZW ¾" 1" 1" 1"
Coil solar - output WYS 1" 1" 1" 1"
Heating water return WY, WYG, WYD 1" 1¼" 1" -
Muff electrical heater MG 1½" 1½" 1½" 1½"
Muff thermometer RT ½" ½" ½" ½"
The capillary tube - closed RK ½" ½" ½" ½"
Dleaning hole W 2" 2" - 133/166/220
Drain ZS, S ¾" ¾" 1" 1"

 

 

 

 

 

 

 

 

 

 

 

                                                                                                                                                                                                                    WGJ-B INOX 1000