WGJ-SQ

characteristics

Exchangers WGJ-SQ - Square standing with all connections from the top, they are designed to heat and store hot water for the needs of flats, houses, small buildings and other objects equipped with a low-temperature hot water boilers of any type.

The tank is covered inside with a layer of special high temperature ceramic enamel.

 

Available models:

 

Catalog number Model EAN
076-10-101 WGJ-SQ 100 5903538206010
076-12-101 WGJ-SQ 120 5903538206027
076-15-101 WGJ-SQ 150 5903538206034

 

technical information
Technical parameters
Type Unit WGJ-SQ 100 WGJ-SQ 120 WGJ-SQ 150
Capacity l 100 120 150
The surface of the coil 0,95 1,1 1,25
The capacity of the coil l 5,2 5,8 6,6

Constant efficiency hot water*

80/10/45°C

70/10/45°C

60/10/45°C

l/h

 

600

515

370

 

690

590

420

 

810

680

490

Constant heating power *

80/10/45°C

70/10/45°C

60/10/45°C

kW

26

21

16

30

24

18

35

28

21

Initial efficiency for hot water * (at temp.of the initial 50 ° C)

80/10/45°C

70/10/45°C

60/10/45°C

l/10min

130

120

110

150

140

130

200

180

160

Demand for heating water m³/h 2,2 2,2 2,2
The resistance of the water flow in the coil mbar 20 25 30
Efficiency factor NL (at temp. Of the initial 50 ° C)   1,0 1,1 1,2
ErP Efficiency Class**   B B B
Operating parameters of the tank

Maximum operating pressure and temperature pr = 0, 6 MPa, tm = 80°C

The parameters of the heating medium

Maximum operating pressure and temperature pr = 0, 6 MPa, tm = 100°C

Weight of exchanger kg 81 91 105
Heating water flow WE   1" 1" 1"
Heating water return WY   1" 1" 1"
Circulation CR   ¾" ¾" ¾"
Cold water ZW   ¾" ¾" ¾"
Hot water CW   ¾" ¾" ¾"
Temperature sensor CT   ½" ½" ½"
Drain OD   ½" ½" ½"

*80°C, 70°C, 60°C - heating water temperature at the entrance to the coil,

 10°C - temperature of the water flow,

 45°C - temperature hot water.

** in accordance with applicable since 26 September 2015. EU Commission Regulation No. 812/2013

 

Dimensions
Type Unit L A B C E F G J K
WGJ-SQ 100 mm 1150 505 505 62,5 130 75 50 125 136
WGJ-SQ 120 mm 1000 615 615 75 130 75 50 130 150
WGJ-SQ 150 mm 1150 615 615 75 130 75 50 130 150

 

unfold fold