EKO-KWP 12, 15, 20, 25, 38, 50
characteristics
Boiler EKO-KWP are designed to work in water central heating systems of houses or multifamily, smaller resorts, workshops, etc.. Central heating systems can be:
open system - having a security in accordance with the requirements of PN-B-02413,
closed system - having a security in accordance with the requirements of PN-B-02414.
Boiler advantages:
- high efficiency,
- economic exploitation,
- mechanical fuel supply,
- automatic in function based on a programmed controller with the possibility of connection DHW sensor (supplied with the boiler) and a room thermostat, mixing valve,
- simple, fast service and maintenance,
- low level emissions of harmful substances.
The boiler is equipped with driver EL480 zPID
Available models:
Model | Catalog number | EAN |
EKO-KWP 12 | 401-12-101/P* | 5903538232897 |
EKO-KWP 12 | 401-12-102/L** | 5903538232903 |
EKO-KWP 15 | 401-15-101/P* | 5903538232330 |
EKO-KWP 15 | 401-15-102/L** | 5903538232347 |
EKO-KWP 20 | 401-20-101/P* | 5903538232934 |
EKO-KWP 20 | 401-20-102/L** | 5903538232941 |
EKO-KWP 25 | 401-25-101/P* | 5903538232354 |
EKO-KWP 25 | 401-25-102/L** | 5903538232361 |
EKO-KWP 38 | 401-38-101/P* | 5903538232378 |
EKO-KWP 38 | 401-38-102/L** | 5903538232385 |
EKO-KWP 50 | 401-50-101/P* | 5903538243268 |
EKO-KWP 50 | 401-50-102/L** | 5903538246276 |
*Feeder on the right side
**Feeder on the left side
technical information
Type | Unit | EKO-KWP | ||||||
12 | 15 | 20 | 25 | 38 | 50 | |||
Nominal power | hard coal | kW | 12 | 15 | 20 | 24 | 38 | 48 |
brown coal | kW | 12 | 15 | 18 | 22 | 35 | 45 | |
Range of power regulation | hard coal | kW | 3,5 - 12 | 4,5 - 15 | 6 - 20 | 7 - 24 | 11 - 38 | 15 - 48 |
brown coal | kW | 3,5 - 12 | 4,5 - 15 | 6 - 18 | 7 - 22 | 10 - 35 | 13,5 - 45 | |
Efficiency | % | 88,5 ÷ 89,9 | ||||||
Heating surface of exchanger | m² | 1,65 | 2,0 | 2,0 | 2,8 | 4,0 | 4,8 | |
Fuel consumption at rated power | kg/h | about 2,0 | about 2,5 | about 2,5 | about 4,0 | about 6,3 | about 8,3 | |
Minimum fuel consumption | kg/h | about 0,8 | about 1,0 | about 1,0 | about 1,5 | about 2,1 | about 2,5 | |
Class | 3 | |||||||
The flue gas temperature | °C | 160 ÷ 250 | ||||||
Boiler weight without water | kg | 325 | 360 | 365 | 410 | 550 | 690 | |
Water capacity | dm³ | 72 | 80 | 80 | 108 | 155 | 200 | |
The outer diameter of the smoke conduit | mm | 160 | 160 | 160 | 160 | 160 | 194 | |
The recommended cross-section of the flue | cm | 16 x 16 | 16 x 16 | 16 x 16 | 20 x 20 | 20 x 20 | 20 x 20 | |
Tray loading aperture | mm | 410 x 500 | 410 x 500 | 410 x 500 | 500 x 600 | 520 x 730 | 530 x 740 | |
Capacity of the tray | dm³/kg | 115/90 | 155/120 | 155/120 | 180/140 | 275/210 | 400/300 | |
The maximum fuel supply by a screw feeder | hard coal | kg/h | about 13,4 | about 18,3 | ||||
brown coal | about 11,0 | about 15,0 | ||||||
Maximum water pressure | bar | 2,5 | ||||||
Recommended temperature of heating water | °C | 65 | ||||||
Max. and min. temp. of heating water | °C | 85/35 | ||||||
Required chimney draft | mbar | 0,1 ÷ 0,25 | 0,35 | |||||
Boiler connections | heating water (output) | external thread 1½" - 1 piece, internal thread 1" - 2 pieces | ||||||
heating water (return) | external thread 1½" - 1 piece | |||||||
Drain | internal thread ½" | |||||||
Supply voltage | 1~230V/50 Hz TN-S | |||||||
Connected load | W | 170 | 260 |
Dimension [mm] | EKO-KWP | |||||
12 | 15 | 20 | 25 | 38 | 50 | |
A | 1140 | 1140 | 1140 | 1170 | 1205 | 1290 |
H | 1100 | 1235 | 1235 | 1330 | 1450 | 1550 |
B | 830 | 830 | 830 | 980 | 1215 | 1230 |
C | 740 | 875 | 875 | 965 | 1090 | 1190 |
D | 560 | 560 | 560 | 590 | 590 | 690 |
F | 80 | 80 | 80 | 80 | 80 | 80 |
G | 340 | 480 | 480 | 580 | 495 | 470 |
I | 900 | 1035 | 1035 | 1130 | 1250 | 1360 |