Controller REG - 07

characteristics

Controller REG-07 is adapted to control the operation of the boiler equipped with a coal feeder, the central heating pump, pump hot water, circulation pump and a fan which fuels combustion of fuel in the boiler. In addition, in emergency situations can change the control mode: from the feeder to the traditional charge. The controller is also equipped with the entrance of the room thermostat, which allows you to change the parameter of the boiler after reaching the desired temperature in the room.

The main task of the controller is to control the administration of the coal and operation of the fan, which feeds fuel combustion in the boiler. On reaching the required heating water temperature controller switches to maintain the temperature. In addition, the controller is equipped with an emergency boiler control mode (feed hopper), through which it is possible to burning like in traditional boiler.

The controller also supports the hot water tank. DHW pump starts working when the controller detects too low temperature of the tank. You can also specify the mode of operation of the pump DHW - priority or not. Additionally, the device has the ability to control the circulation pump. Its task is to ensure continuous water flow (circulation) from the heating device to the receiver. Such a pump provide a constant water temperature. The controller also allows for the control with the room thermostat. This allows you to control the heating in relation to the prevailing temperature in the room. The controller is also equipped with a system of self-control (temperature sensor fault detection) as well as monitoring mechanisms to prevent passage of the boiler work beyond the scope of safety for central heating.

technical information
Technical data
Sensors KTY-210
Measurement range 0 - 120°C
Resolution of measurements 0.1°C
Time of measurement 1 s
Reading data LCD display 2x20
Control outputs
Feeder ~230V 2A (0.8A)
Fan ~230V 2A (0.8A)
The pump of central heating ~230V 2A (0.8A)
The DHW pump ~230V 2A (0.8A)
The circulation pump ~230V 2A (0.8A)
Alarm STB ~230V 2A (0.8A)
Security
Thermal STB (95°C)
Electric Fuse 2A
Inputs
The room thermostat The break contact
Temperature sensor KTY-210
Signaling
LEDs Signalling output states
LCD display Messages, measurements, settings
Power ~230V 50Hz 8VA
Working temperature 5°C - 50°C
Casing protection degree IP20
The dimensions (length x width x height)
The controller module 175 x 65 x 30 mm
Executive module 135 x 90 x 65 mm
Sensors KTY-210

 

 

unfold fold