EKO-KWRW: 40, 50, 60, 70
characteristics
KWRW boiler with water grate, air fan and microprocessor control allows the burning of hard coal, coal dust and biomass of different granulation. The nozzles built in the shell of the exchanger evenly aerate the entire fuel stack.
Boiler advantages:
- high combustion efficiency,
- low operating costs,
- simple attendance and maintenance,
- high-quality control and safety devices,
- rapid assembly during installation of the boiler in the boiler room.
The boiler is equipped with driver EL880 zPID
Available models:
Model | Catalog number | EAN |
EKO-KWRW 40 | 411-40-100 | 5903538232637 |
EKO-KWRW 50 | 411-50-100 | 5903538232644 |
EKO-KWRW 60 | 411-60-100 | 5903538232651 |
EKO-KWRW 70 | 411-70-100 | 5903538232668 |
technical information
Parameter | Unit | 40 kW | 50 kW | 60 kW | 70 kW | |
Nominal heating power | kW | 40 | 50 | 60 | 70 | |
Minimum heat output | kW | 10 | 15 | 25 | 30 | |
Efficiency * | % | 80 | ||||
Efficiency substitute fuel | % | about 75 | ||||
Minimum / maximum temperature of the water | °C | 40 / 85 | ||||
Maximum operating pressure in the boiler | MPa | 0,2 | ||||
Disposable fuel load | kg | 97 | 135 | 210 | 280 | |
Water capacity | dm³ | 123 | 163 | 187 | 216 | |
Heating surface of heat exchanger | m² | 3,6 | 4,6 | 6 | 7 | |
Required chimney draft | Pa | 20 - 35 | ||||
The recommended cross section of the chimney | cm² | about 350 | ||||
The outer diameter of smoke conduit | mm | 160 | 194 | |||
Boiler connections | heating water outlet | external thread 1 ½" - 1 pieces; internal thread 1" - 2 pieces | external thread 2" - 1 pieces; internal thread 1" - 2 pieces | |||
heating water return | external thread 1 ½" - 1 pieces | external thread 2" - 1 pieces | ||||
Drain | internal thread ½" | |||||
* for the primary fuel ** The maximum value for buildings with good thermal insulation and efficient heating system with a maximum demand q = 100 W / m² |