Controller REG - 05
characteristics
Controller REG-05 is adapted to control the operation of the boiler equipped with a coal feeder, the central heating pump, pump hot water circulation pump and a fan which fuels combustion of fuel in the boiler. The controller is also equipped with the entrance of the room thermostat, which allows you to change the parameter of the boiler after reaching the desired temperature in the room.
technical information
Sensors | KTY-210 |
Measurement range | 0 - 120°C |
Resolution measurements | 0,1°C |
Time measurement | 1 s |
Reading data | LCD display 2x20 |
Control outputs | |
Feeder | ~230V 2A (0.8A) |
Fan | ~230V 2A (0.8A) |
The pump of central heating | ~230V 2A (0.8A) |
The DHW pump | ~230V 2A (0.8A) |
The circulation pump | ~230V 2A (0.8A) |
Alarm STB | ~230V 2A (0.8A) |
Security | |
Thermal | STB (95°C) |
Electric | Fuse 2A |
Inputs | |
The room thermostat | The break contact |
Temperature sensors | KTY-210 |
Signaling | |
LEDs | Signalling output states |
LCD Display | Messages, measurements, settings |
Power | ~230V 50Hz 8VA |
Working temperature | 5°C - 50°C |
Casing protection degree | IP20 |
The dimensions (length x width x height) | |
The controller module | 175 x 65 x 30 mm |
Executive module | 135 x 90 x 65 mm |
Sensors | KTY-210 |