Controller REG - 05

characteristics

Controller REG-05 is adapted to control the operation of the boiler equipped with a coal feeder, the central heating pump, pump hot water circulation pump and a fan which fuels combustion of fuel in the boiler. The controller is also equipped with the entrance of the room thermostat, which allows you to change the parameter of the boiler after reaching the desired temperature in the room.

technical information
Technical data
Sensors KTY-210
Measurement range 0 - 120°C
Resolution measurements 0,1°C
Time measurement 1 s
Reading data LCD display 2x20
Control outputs
Feeder ~230V 2A (0.8A)
Fan ~230V 2A (0.8A)
The pump of central heating ~230V 2A (0.8A)
The DHW pump ~230V 2A (0.8A)
The circulation pump ~230V 2A (0.8A)
Alarm STB ~230V 2A (0.8A)
Security
Thermal STB (95°C)
Electric Fuse 2A
Inputs
The room thermostat The break contact
Temperature sensors KTY-210
Signaling
LEDs Signalling output states
LCD Display Messages, measurements, settings
Power ~230V 50Hz 8VA
Working temperature 5°C - 50°C
Casing protection degree IP20
The dimensions (length x width x height)
The controller module 175 x 65 x 30 mm
Executive module 135 x 90 x 65 mm
Sensors KTY-210

 

unfold fold