Controller REG - 09

characteristics

The controller REG - 09 is designed to control the operation of the boiler equipped with a coal feeder, the central heating pump, pump hot water, circulation pump and a fan which fuels combustion of fuel in the boiler. The controller is also equipped with the entrance of the room thermostat, which allows you to change the parameter of the boiler after reaching the desired temperature in the room. Additionally, the device is programmed parameters to work with different types of fuels, eg. Coal coal, pellets, oats, had so on.

The main task of the controller is to control the administration of the coal and operation of the fan, which feeds fuel combustion in the boiler. On reaching the required heating water temperature controller switches to maintain the temperature.

The controller also supports the hot water tank. DHW pump starts working when the controller detects too cold tray. You can also specify the mode of operation of the pump DHW - priority or not.

Additionally, the device has the ability to control the circulation pump. Its task is to ensure continuous water flow (circulation) from the heating device to the receiver. Such a pump provides a constant temperature water.

The controller also allows for the control with the room thermostat. This allows you to control the heating in relation to the prevailing temperature in the room.

The controller is also equipped with a system of self-control (temperature sensor fault detection) as well as monitoring mechanisms to prevent passage of the boiler work beyond the scope of safety for central heating.

technical information
Specification
Technical data
Sensors KTY-210
Measurement range 0 - 120°C
Resolution measurements 0,1°C
Time measurement 1 s
Reading data 2x20 LCD Display
Control outputs
Feeder ~230V 2A ( 0.8A )
Fan ~230V 2A ( 0.8A )
The pump central heating ~230V 2A ( 0.8A )
Pump hot water ~230V 2A ( 0.8A )
The circulation pump ~230V 2A ( 0.8A )
Alarm STB ~230V 2A ( 0.8A )
Security
Thermal STB (95°C)
Electric Fuse 2A
Inputs
The room thermostat The break contact
Temperature sensor KTY-210
Signaling
LEDs Signalling output states
LCD Display Messages, measurements, settings
Power ~230V 50 Hz 8 VA
Working temperature 5°C - 50°C
Housing protection standard IP 20
The dimensions (length x width x height)
The controller module 175 x 65 x 30 mm
Executive module 135 x 90 x 65 mm
Sensors KTY-210

 

 