EKO-KWP Premium: 15, 20, 25, 38, 50
characteristics
KWP Premium solid fuel boilers are designed to operate in central heating systems.
Boiler advantages:
- fuel container opening sensor,
- feeder operation sensor,
- pressure equalization system,
- Eco Save System innovative deflector,
- Tech PID controller,
- welded by robots,
- very high efficiency,
- optional cast-iron grate.
The boiler is equipped with driver EL480 zPID
Model | Catalog number | EAN |
EKO-KWP 12 P | 402-12-101/P | 5903538243787 |
EKO-KWP 12 L | 402-12-102/L | 5903538243794 |
EKO-KWP 15 P | 402-15-101/P | 5903538243800 |
EKO-KWP 15 L | 402-15-102/L | 5903538243817 |
EKO-KWP 20 P | 402-20-101/P | 5903538243824 |
EKO-KWP 20 L | 402-20-102/L | 5903538243831 |
EKO-KWP 25 P | 402-22-101/P | 5903538243848 |
EKO-KWP 25 L | 402-25-102/L | 5903538243855 |
EKO-KWP 38 P | 402-38-101/P | 5903538243862 |
EKO-KWP 38 L | 402-38-102/L | 5903538243879 |
EKO-KWP 50 P | 402-50-101/P | 5903538243886 |
EKO-KWP 50 L | 402-50-101/L | 5903538243893 |
technical information
KWP Premium | A | H | B | C | D | F | G | I |
12 | 1140 | 1100 | 830 | 740 | 560 | 80 | 340 | 900 |
15 | 1140 | 1235 | 830 | 875 | 560 | 80 | 480 | 1035 |
20 | 1140 | 1235 | 830 | 875 | 560 | 80 | 480 | 1035 |
25 | 1170 | 1330 | 980 | 965 | 590 | 80 | 580 | 1130 |
38 | 1205 | 1450 | 1215 | 1090 | 590 | 80 | 495 | 1250 |
50 | 1290 | 1550 | 1230 | 1190 | 690 | 80 | 470 | 1360 |
Parameter | Unit | EKO-KWP premium | ||||||
12 | 15 | 20 | 25 | 38 | 50 | |||
Nominal power | coal | kW | 12 | 15 | 20 | 24 | 38 | 48 |
lignite | kW | 12 | 15 | 20 | 24 | 38 | 48 | |
Range of power regulation | coal | kW | 3,5-12 | 4,5-15 | 6-20 | 7-24 | 11-38 | 14,4-48 |
lignite | kW | 3,5-12 | 4,5-15 | 6-20 | 7-24 | 11-38 | 14,4-48 | |
efficiency/ for coal/ | % | 86,6 ÷ 88,3 | ||||||
Heating surface of exchanger | m² | 1,65 | 2,0 | 2,0 | 2,8 | 4,0 | 4,8 | |
Fuel consumption at rated power | kg/h | about 2,0 | about 2,5 | about 2,5 | about 4,0 | about 6,3 | about 8,3 | |
Minimum fuel consumption | kg/h | about 0,8 | about 1,0 | about 1,0 | about 1,5 | about 2,1 | about 2,5 | |
Class | 4 | |||||||
The flue gas temperature | °C | 160 ÷ 250 | ||||||
Boiler weight without water | kg | 325 | 360 | 365 | 410 | 550 | 690 | |
Water capacity | dm³ | 72 | 80 | 80 | 108 | 155 | 200 | |
The outer diameter of the flue | mm | 160 | 160 | 160 | 160 | 160 | 194 | |
The recommended cross-section of the flue | cm | 16 x 16 | 16 x 16 | 16 x 16 | 20 x 20 | 20 x 20 | 20 x 20 | |
Fuel storage hole | mm | 410 x 500 | 410 x 500 | 410 x 500 | 500 x 600 | 520 x 730 | 530 x 740 | |
Tank capacity | dm³/kg | 115/90 | 155/120 | 155/120 | 180/140 | 275/210 | 400/300 | |
The maximum fuel supply by a screw feeder | coal | kg/h | about 13,4 | about 18,3 | ||||
lignite | about 11,0 | about 15,0 | ||||||
The maximum water pressure | bar | 2,5 | ||||||
The recommended operating temperature of heating water | °C | 65 | ||||||
Max. and min. heating water temperature | °C | 85/35 | ||||||
Required chimney draft | mbar | 0,1 ÷ 0,25 | 0,35 | |||||
Boiler connections | heating water (output) | external thread 1½" - 1 piece, internal thread 1" - 2 pieces | ||||||
heating water (return) | external thread 1½" - 1 piece | |||||||
Drain | internal thread ½" | |||||||
Supply voltage | 1~230V / 50Hz TN-S | |||||||
Connected load | W | 270 |