EKO-KWP MDP: 15, 20, 25
characteristics
Boilers EKO-KPW MDP are intended for operation in water central heating of single- and multi-family houses, smaller recreation centers, workshops, etc.
Central heating systems can be:
- open system - having a security in accordance with the requirements of PN-B-02413,
- closed system - having a security in accordance with the requirements of PN-B-02414..
Boiler advantages:
- the possibility of burning biomass,
- automatic firing up,
- high energy efficiency,
- economic exploitation,
- mechanical fuel supply,
- safe, simple, convenient operation and maintenance,
- low emissions,
The boiler is equipped with driver EL-483 or EL480 zPID multi
Available models:
Model | Catalog number | EAN |
EKO-KWP MDP 15 P | 446-15-101/P | 5903538246160 |
EKO-KWP MDP 15 L | 446-15-102/L | 5903538246177 |
EKO-KWP MDP 20 P | 446-20-101/P | 5903538246184 |
EKO-KWP MDP 20 L | 446-20-102/L | 5903538246191 |
EKO-KWP MDP 25 P | 446-25-101/P | 5903538246207 |
EKO-KWP MDP 25 L | 446-25-102/L | 5903538246214 |
technical information
Parameter | Unit | EKO-KWP MDP | |||
15 | 20 | 25 | |||
Nominal power | kW | 15 | 20 | 25 | |
Range of power regulation | kW | 4,5 - 15 | 6 - 20 | 7,5 - 25 | |
Efficiency | % | about 91 | |||
Class | 5 | ||||
The flue gas temperature | °C | 110 ÷ 150 | |||
Boiler weight without water | kg | 420 | 460 | 515 | |
Water capacity | dm³ | 80 | 90 | 115 | |
The outer diameter of the flue | mm | 160 | |||
The recommended cross-section of the flue | cm | 20 x 20 | |||
Tray loading aperture | mm | 420 x 300 | 420 x 440 | 420 x 520 | |
Capacity of the tray | dm³ | 225 | 275 | 275 | |
Max. operating pressure of the water | bar | 2,5 | |||
The recommended operating temperature of heating water | °C | 65 | |||
Max. and min. temp. of heating water | °C | 85/45 | |||
Required chimney draft | mbar | 0,1 ÷ 0,25 | |||
Boiler connections | heating water (output) | external thread 1½" - 1 piece, internal thread 1" - 2 pieces | |||
heating water (return) | external thread 1½" 1 piece | ||||
Drain | internal thread ½" | ||||
Supply voltage | 1~230V/50Hz TN-S | ||||
Power consumption during operation with nominal power | W | 280 | |||
Power consumption during firing up | W | 860 |
EKO-KWP MDP | A | B | C | D | E | F | G | H | I |
15 | 560 | 1180 | 760 | 1275 | 82 | 450 | 1280 | 1510 | 315 |
20 | 560 | 1180 | 830 | 1320 | 82 | 450 | 1330 | 1560 | 315 |
25 | 590 | 1210 | 910 | 1365 | 82 | 450 | 1370 | 1600 | 345 |